Fiber Optic Duct
Enclosed duct with sliding covers for optical fiber routing in data centers.
- MaterialAluminum
- FinishPlain
- Width100–300 mm
Seismic bracing for cable trays, pipes and ducts in earthquake zones.

Seismic support brackets restrain cable trays, conduits and MEP services during earthquakes, as required by building codes.
Hot-dip galvanized components with adjustable angles; engineering layout support available.
Request a Quote| Model | KY-SB-L |
|---|---|
| Type | Data Center & Accessories |
| Material | Steel |
| Surface Finish | Hot-dip Galv. |
| Thickness | 2.0–5.0 mm |
| Length | Custom |
| Standard | Designed to GB 50981 for seismic bracing of MEP services |
| Applications | Public buildings, Hospitals & schools, Metro & rail, Industrial plants |
| Place of Origin | Shanghai, China |
| Customization | OEM / ODM accepted |
| Brand | KAIYUAN |
| Standards | Sections are built to the dimensional and load classes of EN 61537 / NEMA VE 1. This is a referenced dimensional and load classification, not a product certification. |
| Model | Width | Height | Thickness | Load class |
|---|---|---|---|---|
| KY-SB-L | — | — | 2.5 mm | Heavy |
| KY-SB-LG | — | — | 2.5 mm | Heavy |
| KY-SB-MD | — | — | 3.0 mm | Heavy |
Other widths, heights and thicknesses are available on request.
Dimensional drawing for reference. Custom sizes available on request.
Braces attach to the structure with M12 anchors and to the tray with swivel clamps; spacing follows the seismic design category — typically lateral braces every 6 m and longitudinal every 12 m, subject to project calculation.
Select brace type (lateral / longitudinal / multi-directional) and strut size from the seismic requirement of the project. Factory-tested assemblies with calculation reports simplify inspection and acceptance.
| Applicable section range | Supports 50–600 mm wide tray; M12–M16 fixings; bracket members 2.0–5.0 mm thick |
|---|---|
| Recommended support span | Lateral brace every 6 m and longitudinal brace every 12 m as a starting point — final spacing is set by the project seismic calculation |
| Maximum fill ratio | Not applicable — a support does not carry cable. The tray it supports is sized on its own fill ratio (≤ 40%) |
Figures follow the same rules we apply when checking your cable schedule. Send us the schedule and we confirm the section with the quotation.
| Applicable section range | Supports 50–600 mm wide tray; M12–M16 fixings; bracket members 2.0–5.0 mm thick |
|---|---|
| Recommended support span | Lateral brace every 6 m and longitudinal brace every 12 m as a starting point — final spacing is set by the project seismic calculation |
| Maximum fill ratio | Not applicable — a support does not carry cable. The tray it supports is sized on its own fill ratio (≤ 40%) |
Figures follow the same rules we apply when checking your cable schedule. Send us the schedule and we confirm the section with the quotation.
| Packing | Steel bundle / wooden case / carton with edge protection |
|---|---|
| Standard length | 3 m (custom lengths on request) |
| MOQ | 1×20GP container; smaller trial orders negotiable |
| Lead time | 20–30 days after deposit |
| Loading port | Shanghai, China |
| Payment terms | T/T 30% deposit, balance against B/L copy |
| Sample | Free sample, freight collect |
| OEM / ODM | Accepted — your size, color and logo |
Our bracing is designed to GB 50981, the Chinese code for seismic design of mechanical and electrical services, and the components are hot-dip galvanized for corrosion resistance. Tell us the project country and we will confirm which local code the design should be checked against.
Yes. Send the tray route, support spacing, cable load and the project's seismic intensity or acceleration parameter, and we will return a bracing layout with member sizes and anchor specifications that your consultant can review and stamp locally.
A set normally pairs a lateral brace with a longitudinal brace at each braced point, using adjustable angle brackets, threaded rods and anchors. The adjustable angles absorb site tolerance, so the bracing can be installed after the tray run is fixed rather than being built in from the start.
We are a manufacturer with our own production lines in Shanghai, China — direct factory supply with OEM/ODM support.

Enclosed duct with sliding covers for optical fiber routing in data centers.
Send your cable schedule, drawing or size list — we reply with an official quotation within 24 hours.