Product Range

Perforated Cable Tray

Ventilated perforated-bottom tray for moderate loads with heat dissipation.

Perforated Cable Tray photo

Product Overview

Perforated cable tray combines the strength of a solid tray with ventilation holes that dissipate cable heat. It is the most widely used tray type for indoor power and control cabling.

Supplied straight, curved, with tee/cross fittings and covers to form complete runs. A ventilated photovoltaic version in galvanized or zinc-aluminum-magnesium steel (zinc layer up to 275 g/m²) is engineered for ground, distributed and rooftop PV plants.

Request a Quote

Material & Finish Options

Perforated Cable Tray — Pre-Galvanized Steel
Pre-Galvanized Steel
Perforated Cable Tray — Hot-Dip Galvanized (GC, ISO 1461)
Hot-Dip Galvanized (GC, ISO 1461)
Perforated Cable Tray — Water-Drop Profile with Buckle Lock
Water-Drop Profile with Buckle Lock

Other finishes and sizes on request — send your specification for a same-week quote.

Specifications

ModelKY-PF-100
TypeCable Tray Systems
MaterialSteel
Surface Finishhdg / Zn-Al-Mg (275 g/m²)
Width50–600 mm
Thickness0.8–2.0 mm
Length2–3 m
StandardBuilt to IEC 61537 dimensional & load classes
ApplicationsIndustrial plants, Commercial buildings, Infrastructure, Warehouses
Place of OriginShanghai, China
CustomizationOEM / ODM accepted
BrandKAIYUAN
StandardsSections are built to the dimensional and load classes of EN 61537 / NEMA VE 1. This is a referenced dimensional and load classification, not a product certification.

Standard Size Range

ModelWidthHeightThicknessLoad class
KY-PF-100100 mm50 mm1.0–1.5 mmLight
KY-PF-200200 mm100 mm1.2–1.5 mmMedium
KY-PF-300300 mm100 mm1.5–2.0 mmMedium
KY-PF-400400 mm150 mm2.0–2.5 mmHeavy

Other widths, heights and thicknesses are available on request.

Technical Drawing

KAIYUAN ELECTRICDWG NO. KY-PERFORATEDTRAYSCALE: NTSPØ punchedW 50–600 mmH 50–100

Dimensional drawing for reference. Custom sizes available on request.

Key Features

  • Perforated bottom for heat dissipation
  • Lightweight yet strong
  • Wide fitting range for complete routing
  • Galvanized or powder-coated finishes

Applications

Industrial plantsCommercial buildingsInfrastructureWarehouses

Installation & Maintenance

Perforated tray installs on brackets at 1.5–2 m spans; the perforations allow cable ties to secure bundles anywhere along the run. Covers add protection where dust or falling objects are a concern.

Selection Guide

The workhorse of indoor cable management — suits power and data cables in factories, commercial buildings and infrastructure. Perforation improves heat dissipation while keeping moderate mechanical protection.

Quick Selection Table

Applicable section range50–600 mm wide × 0.8–2.0 mm sheet
Recommended support span1.5–2 m on brackets
Maximum fill ratio≤ 40% for power and control cable; for PV DC cable ≤ 30% with a further 20% reserved for later string additions

Figures follow the same rules we apply when checking your cable schedule. Send us the schedule and we confirm the section with the quotation.

Quick Selection Table

Applicable section range50–600 mm wide × 0.8–2.0 mm sheet
Recommended support span1.5–2 m on brackets
Maximum fill ratio≤ 40% for power and control cable; for PV DC cable ≤ 30% with a further 20% reserved for later string additions

Figures follow the same rules we apply when checking your cable schedule. Send us the schedule and we confirm the section with the quotation.

Packaging & Delivery

PackingSteel bundle / wooden case / carton with edge protection
Standard length3 m (custom lengths on request)
MOQ1×20GP container; smaller trial orders negotiable
Lead time20–30 days after deposit
Loading portShanghai, China
Payment termsT/T 30% deposit, balance against B/L copy
SampleFree sample, freight collect
OEM / ODMAccepted — your size, color and logo

FAQ

What is the difference between standard perforated and water-drop profile?

Standard perforated tray uses a regular punched pattern and is the general-purpose choice. The water-drop (buckle-lock) profile has a formed edge that stiffens the side rail and lets sections lock together without separate splice plates, which speeds up installation on long runs and gives a cleaner finished appearance.

When does perforated tray need a cover?

Add a cover where dust, dripping water, falling objects or sunlight (UV) can reach the cables, or where the tray is visible in public areas. In clean indoor ceilings with power and data cable, open perforated tray is normally left uncovered so heat can escape.

What is the Zn-Al-Mg option and when is it worth it?

Zinc-aluminium-magnesium coated steel (275 g/m²) gives roughly 2–3 times the corrosion resistance of standard hot-dip galvanizing and self-heals at cut edges, which makes it popular for solar farms, coastal rooftops and agricultural buildings where re-coating is impossible. It is a good middle ground between galvanized and stainless on cost.

Are you a factory or a trading company?

We are a manufacturer with our own production lines in Shanghai, China — direct factory supply with OEM/ODM support.

Related Products

View All Products

A Trusted Partner for Cable Infrastructure

Send your cable schedule, drawing or size list — we reply with an official quotation within 24 hours.