Channel Cable Tray (Solid Bottom)
Closed-bottom channel tray protecting cables from dust and moisture.
- MaterialSteel
- FinishHot-dip Galv.
- Width50–600 mm
Engineering alloy plastic tray — insulation and chemical resistance.

Alloy plastic cable tray is extruded from modified engineering plastic alloys, providing electrical insulation, chemical resistance and zero rust.
A practical choice where metal trays are not allowed or corrosive fumes exist.
Request a Quote| Model | KY-CT-100 |
|---|---|
| Type | Cable Tray Systems |
| Material | FRP |
| Surface Finish | Plain |
| Width | 50–400 mm |
| Thickness | 2.0–4.0 mm |
| Length | 2–3 m |
| Standard | Built to our internal standard QB |
| Applications | Chemical plants, Water treatment, Food processing, Plating workshops |
| Place of Origin | Shanghai, China |
| Customization | OEM / ODM accepted |
| Brand | KAIYUAN |
| Standards | Sections are built to the dimensional and load classes of EN 61537 / NEMA VE 1. This is a referenced dimensional and load classification, not a product certification. |
| Model | Width | Height | Thickness | Load class |
|---|---|---|---|---|
| KY-CT-100 | 100 mm | 50 mm | 1.0–1.5 mm | Light |
| KY-CT-200 | 200 mm | 100 mm | 1.2–2.0 mm | Medium |
| KY-CT-300 | 300 mm | 100 mm | 1.5–2.0 mm | Medium |
| KY-CT-400 | 400 mm | 150 mm | 2.0–2.5 mm | Heavy |
Other widths, heights and thicknesses are available on request.
Dimensional drawing for reference. Custom sizes available on request.
Snap-together design installs without special tools; the lightweight sections allow longer spans between supports at lower labor cost. UV-stabilized compound suits outdoor exposure.
Choose alloy plastic (PVC alloy) tray where insulation and chemical resistance are priorities — plating lines, battery rooms, substations and cleanrooms. It will not rust, is halogen-free flame-retardant and weighs far less than metal tray.
| Applicable section range | 50–400 mm wide × 2.0–4.0 mm wall |
|---|---|
| Recommended support span | 1.5–2 m on hangers, brackets or trapeze kits — the same support logic as steel tray |
| Maximum fill ratio | ≤ 40% for power and control cable |
Figures follow the same rules we apply when checking your cable schedule. Send us the schedule and we confirm the section with the quotation.
| Applicable section range | 50–400 mm wide × 2.0–4.0 mm wall |
|---|---|
| Recommended support span | 1.5–2 m on hangers, brackets or trapeze kits — the same support logic as steel tray |
| Maximum fill ratio | ≤ 40% for power and control cable |
Figures follow the same rules we apply when checking your cable schedule. Send us the schedule and we confirm the section with the quotation.
| Packing | Steel bundle / wooden case / carton with edge protection |
|---|---|
| Standard length | 3 m (custom lengths on request) |
| MOQ | 1×20GP container; smaller trial orders negotiable |
| Lead time | 20–30 days after deposit |
| Loading port | Shanghai, China |
| Payment terms | T/T 30% deposit, balance against B/L copy |
| Sample | Free sample, freight collect |
| OEM / ODM | Accepted — your size, color and logo |
The tray itself is electrically insulating, so it does not carry fault current and does not need bonding as a metal tray would. Note that your local code may still require a separate earth conductor run alongside the tray for the cables — that is a cabling decision, not a property of the tray.
Yes, a flame-retardant grade is available for tunnels, metro and enclosed spaces where a plastic raceway must meet fire-performance requirements. Tell us the fire class your specification calls for and we will quote the matching grade rather than the standard one.
It uses the same support logic — hangers, brackets or trapeze kits on 1.5–2 m spans — but the tray is light enough for one person to lift a 3 m length, and it can be cut and drilled with ordinary woodworking tools. No welding, no hot work and no re-coating of cut edges.
We are a manufacturer with our own production lines in Shanghai, China — direct factory supply with OEM/ODM support.

Closed-bottom channel tray protecting cables from dust and moisture.

Electrostatic powder-coated tray with strong corrosion resistance and color options.

Fiberglass reinforced plastic tray — non-conductive and corrosion-proof.
Send your cable schedule, drawing or size list — we reply with an official quotation within 24 hours.